Child pages
  • 201704 - Public report
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Unscheduled:

  • April 12th: The Adobe connect service for SUNET was unstable due to a broadcast storm in our environment.
  • April 8th: All interfaces on umu-r1 flapped and then showed a minor alarm on a controller board. After a re-seat of the controller board the alarm cleared.
  • April 3rd: The link to oru-r1 was down. Resolved by restarting the MPC card.
  • March 31st: The MPLS - L2C between UU and Campus Gotland went down during the migration of the link to the new switch at Uppsala (uu-sw2). This has now been fixed.

Scheduled:

  • April 28th: Routing engine was switched on router jkg-r1.
  • April 25th: Carrier performed maintenance on the connection between Gällivare and Jokkmokk.
  • April 25th: The core router in Västerås was upgraded to a new software release.
  • April 24th: The controller board on router hb-r2 was re-seated to clear the alarm.
  • April 12th: Control board on router umu-r1.sunet.se was reseated and the fiber between umu-r1 and the POP was measured. The router is alarm free now.
  • April 7th: We removed the debug image from the router in Trollhättan, hv-r1.
  • April 7th: A card was restarted in the Karlstad router in order to fix an alarm.

Scope

Unscheduled

Scheduled

Total

Hardware

1 pcs 00:03

2 pcs 00:22

3 pcs 00:25

Link

2 pcs 6d 05:18

2 pcs 03:35

4 pcs 6d 08:53

None

0 pcs

2 pcs 00:24

2 pcs 00:24

Routing

1 pcs 02:24

1 pcs 00:45

2 pcs 03:09

Software

0 pcs

0 pcs

0 pcs

  • No labels