Child pages
  • 201401 - Public report
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

Unscheduled:

  • January 29th: The green link to Örebro suffered an outage due to a fiber cut in suppliers network.
  • January 16th: There was a short outage in the south red network, no FRO was found
  • January 16th: A broken amplifier in Tuggen caused outage on the north red network between Tuggen and Umeå. The faulty amplifier has been replaced.
  • January 8th: The was an outage on SUNET north RED network due to a fiber break in Sollentuna.

Scheduled:

  • January 29th: We did an upgrade the software on a transmission node in the west red network in Västerås
  • January 27th: Supplier performed a fibre control due to a signal degradation and found a broken attenuator that was replaced.
  • January 20th: Hardware replacement was done to clear Equipment failure alarms in one of our DWDM nodes in Växjö

Scope

Unscheduled

Scheduled

Total

Hardware

0 pcs

2 pcs 00:16

2 pcs 00:16

Link

4 pcs 1d 03:10

1 pcs 00:02

5 pcs 1d 03:12

Routing

0 pcs

0 pcs

0 pcs

Software

0 pcs

0 pcs

0 pcs

  • No labels