Unscheduled:

  • February 21st: The link between KI and HK went down due to unannounced maintenance.
  • February 19th: Issue with a FPC-card in router sthb-r2 caused multiple links to go down. Solved with a restart of the card.
  • February 17th: The link between gu-r2 and gbg7-r2 went down after fiber maintenance on SUNETTICKET-7617 due to human error.
  • February 16th: Fault on fiber stretch in between Karlstad and Borgvik after the maintenance work notified on SUNETTICKET-7607.  
    The fiber patch was not properly inserted after the maintenance work which was later fixed by the technician and services were restored.
  • February 15th: CPE sdt-c1 went down due to outage in provider network.
  • February 9th: The link between Järpen and Kopperå went down. The outage were due to a fiber break.
  • February 2nd: The link between Stockholm and Västerås went down. This was due to an unannounced planned work by provider.
  • February 1st: Link to customer OSO went down. No RFO found.
  • February 1st: CPE lin-c2 became unreachable. RFO unknown.
  • January 31st: Our link between Karlstad and Örebro is down. This was due to a fiber break between LBA (Örebro) and BBG (Björneborg). We also had a broken patch in BBG that the technician had to replace.

Scheduled:

  • February 23rd: Provider will performed fiber maintenance that affected the link between Tulegatan - Karolinska Institutet.
  • February 23rd: Fiber provider performed a planned maintenance that affected the link towards Stockholm International Peace Research Institute.
  • February 22nd: Provider performed maintenance in Karlstad that affected the link between Karlstad and Mittuniversitetet Östersund also link between Karlstad and Luleå.
  • February 22nd: Subprovider performed a planned maintenance between Korea - Singapore and due to parallel ongoing maintenance in Hongkong the connection between KI - Hongkong was affected.
  • February 17th: Maintenance performed to migrate interface connected to Moderna Museet in Malmö.
  • February 16th: Provider performed network maintenance in Göteborg that affected links towards CTH and GU.
  • February 9th: Provider performed maintenance in Karlstad that affected the link between Karlstad and Mittuniversitetet Östersund also link between Karlstad and Luleå.
  • February 9th: Provider performed maintenance in Karlstad that affected links between Karlstad - Luleå, Karlstad - Trollhättan and AW towards Oslo.
  • February 7th: Provider performed maintenance in Karlstad that affected links to Trollhättan and AW links in Norway.
  • February 7th: Provider performed maintenance in Karlstad that affected link to Mittuniversitetet and SUNET backbone.

Scope

Unscheduled

Scheduled

Total

Hardware

1 pcs 08:28

0 pcs

1 pcs 08:28

Link

6 pcs 2d 13:03

9 pcs 15:56

15 pcs 3d 03:59

None

3 pcs 06:32

1 pcs 00:11

4 pcs 06:43

Routing

0 pcs

0 pcs

0 pcs

Software

0 pcs

0 pcs

0 pcs

  • No labels