Unscheduled:

  • April 24th: Link was down between hkr-r1 and ksd-r1. Provider couldn't see any disturbances due to the connection being a dark fiber with no active monitoring. No RFO
  • April 22nd: The link between routers oru-r1 - lba-r1 was down due to a fiber break which now has been fixed.
  • April 19th: There is an issue on the fiber stretch between Dingle (MUN17) and Strömstad (STD24) with several short flaps. RFO from provider: 'Unknown'
  • April 15th: wiki.sunet.se went down. Services has restored after reboot.
  • March 30th: One of the 100G links between the core router in Linköping and Norrköping was down. It was due to a hardware issue which has been fixed now.

Scheduled:

  • April 29th: SUNET performed emergency wavelength optimisation on the core link between Kiruna and Falun together with hardware provider.
  • April 28th: SUNET performed an emergency maintenance on the UNINETT wavelength between Oslo and Trondheim.
  • April 28th: SUNET performed software upgrade on the routers in Falun (fln4-r1) and the Halmstad (hh-r1).
  • April 27th: The router bth-r2 was upgraded to a newer software version.
  • April 27th: The equipment at current ILA site Junosuando was migrated over to a new site.
  • April 26th: SUNET performed software upgrade on the core routers in Växjö (vxj-r1) and Trollhättan (trh-r1).
  • April 24th: Supplier performed emergency fiber maintenance in the stretch between Boden and Luleå.
  • April 22nd: SUNET performed emergency wavelength optimisation on the core link between Kiruna and Falun.
  • April 19th: SUNET performed maintenance on the optical node in Untra. It didn't resolve the issue in SUNETTICKET-7718.
  • April 16th: Due to errors showing on SUNET core router in Stockholm, a faulty line card was restarted.
  • April 13th: Provider performed an optocable maintenance on the link between Holmagärde (HGE) and Halmstad (HSD1).
  • April 12th: Supplier performed cable work in Kristinehamn that affected the IP-VPN customer connection for RISE Öståsgatan 25 Bäckhammar Kristinehamn.
  • April 12th: Provider performed an optocable maintenance on the link between Holmagärde (HGE) and Halmstad (HSD1).
  • April 12th: Supplier performed fiber maintenance in Ånge, Sweden.
  • April 12th: FPC0 on oru-r2 was restarted in order to clear minor alarm.
  • February 22nd: Provider performed a planned maintenance that affected the link between Karlstad - Luleå.

Scope

Unscheduled

Scheduled

Total

Hardware

1 pcs 1d 16:19

0 pcs

1 pcs 1d 16:19

Link

3 pcs 14:09

9 pcs 1d 15:48

12 pcs 2d 05:57

None

0 pcs

5 pcs 01:02

5 pcs 01:02

Routing

0 pcs

0 pcs

0 pcs

Software

1 pcs 14:38

2 pcs 01:32

3 pcs 16:10