div |
---|
Unscheduled: - August 28th: There was an outage on SUNET west green affecting the redundancy towards Mälardalens Högskola. The issue was a faulty card in a transmission node which was replaced.July 15th: Multiple outages were
- noticed in South Red network. The problem was fixed by changing the fiber in amplifier sites.August 26th: There was an outage on the north red network caused by equipment failure on a node in Uppsala.
Scheduled: - August 25th: The Two transponder cards were replaced in transmission nodes in Västerås.
- August 23rd: A service affecting work was carried out in order restore the management on a node in Växjö.
- August 1st: An emergency maintenance was performed on the south red network to troubleshoot recent issues tracked in SUNETTICKET-1433.
|
Scope | Unscheduled | Scheduled | Total |
---|
Hardware | 0 2 pcs 3d 21:19
| 1 2 pcs 0002:1450 1 | 4 pcs 4d 00:1409 |
---|
Link | 1 0 pcs 01:04 | 2 1 pcs 0200:4206 | 3 1 pcs 0300:4606 |
---|
None | 1 0 pcs 1d 07:46 | 0 pcs | 1 0 pcs 1d 07:46 |
---|
Routing | 0 pcs | 0 pcs | 0 pcs |
---|
Software | 0 pcs | 0 pcs | 0 pcs |
---|
|