- had an outage due to unannounced planned work.
- February 22nd: We lost connection to router fls-r1 in Filipstad for a while. No RFO found.
Scheduled: - March 27th: Supplier performed network maintenance, relocation of fiber on the Hjälta-Norrtjärn link.
- March 16th: Performed sw upgrade of uu-r2.
- March 11th: Supplier performed cable maintenance between Växjö and Visby.
- March 4th: Investigation was performed to diagnose fiber or hardware problem.
- March 3rd: Supplier performed fiber testing on the stretch between Litslena and Uppsala.
|
Scope | Unscheduled | Scheduled | Total |
---|
Hardware | 0 pcs | 0 pcs | 0 pcs |
---|
Link | 7 pcs 2d 05:10 | 2 pcs 02:06 | 9 pcs 2d 07:16 |
---|
None | 3 pcs 1d 02:17 | 3 pcs 06:15 | 6 pcs 1d 08:32 |
---|
Routing | 0 pcs | 0 pcs | 0 pcs |
---|
Software | 0 pcs | 0 pcs | 0 pcs |
---|
|