{div}
Unscheduled:
* February 10th: There was an outage on the red link between SUNET and UmU caused by hardware failure
* January 31st: We had a problem with a transmission card restarting. The card was replaced.
* January 28th: Outage detected on 1GE links between SUNET and Onsala rymdobservatorium was caused by a faulty trasmission board that was replaced
* January 25th: A transmission card in the Blue network suffered multiple power cycles and was replaced.

Scheduled:
* February 24th: Supplier performed a planned maintenance.
* February 14th: A core router was upgraded from a Juniper T640 router to a T1600 router.
* February 13th: A switch was replaced to solve a loss of management problem.
* February 11th: Sitevision was upgraded in order to solve a security bug.
* February 11th: There was a planned work in the west red network.
* February 6th: There was a degraded signal between in SUNET DWDM between the core sites caused by a faulty attenuator. The attenuator was removed.
* February 5th: Software upgrade was performed on SUNET routers.
* February 5th: Software upgrade was performed on SUNET routers.
* February 4th: Software upgrade was performed on SUNET routers.
* February 4th: SUNET's supplier performed a planned cable reconnection maintenance on one of the circuits between Stockholm and Visby.
{div}
div

Unscheduled:

  • February 10th: There was an outage on the red link between SUNET and UmU caused by hardware failure
  • January 31st: We had a problem with a transmission card restarting. The card was replaced.
  • January 28th: Outage detected on 1GE links between SUNET and Onsala rymdobservatorium was caused by a faulty trasmission board that was replaced
  • January 25th: A transmission card in the Blue network suffered multiple power cycles and was replaced.

Scheduled:

  • February 24th: Supplier performed a planned maintenance.
  • February 14th: A core router was upgraded from a Juniper T640 router to a T1600 router.
  • February 13th: A switch was replaced to solve a loss of management problem.
  • February 11th: Sitevision was upgraded in order to solve a security bug.
  • February 11th: There was a planned work in the west red network.
  • February 6th: There was a degraded signal between in SUNET DWDM between the core sites caused by a faulty attenuator. The attenuator was removed.
  • February 5th: Software upgrade was performed on SUNET routers.
  • February 5th: Software upgrade was performed on SUNET routers.
  • February 4th: Software upgrade was performed on SUNET routers.
  • February 4th: SUNET's supplier performed a planned cable reconnection maintenance on one of the circuits between Stockholm and Visby.

    Scope

    Unscheduled

    Scheduled

    Total

    Hardware

    1 pcs 00:19

    2 pcs 00:30

    3 pcs 00:49

    Link

    3 pcs 00:27

    4 pcs 01:29

    7 pcs 01:56

    None

    0 pcs

    0 pcs

    0 pcs

    Routing

    0 pcs

    0 pcs

    0 pcs

    Software

    0 pcs

    4 pcs 05:18

    4 pcs 05:18