Unscheduled:
* January 25th: A fiber break in Borlänge caused an outage on DU´s redundancy.
* January 23rd: A transmission card restarted in SUNET's equipment in Umeå, causing an outage on the North Red network.
* January 22nd: There was an outage on the link to HH.
* January 17th: A router restarted due to a software bug.
* January 14th: A faulty transmission card caused outages on the link between Kiruna and Luleå. The faulty card has been replaced.
* January 5th: A transmission card on SUNET's equipment in Tuggen restarted, causing an outage on the NORTH Red network.
* January 3rd: A software bug caused a SUNET core router to become unreachable.
* January 3rd: There was a link outage in Halmstad om the South Green network, no reason for the outage was found.

Scheduled:
* January 24th: Emergency maintenance was performed in order to troubleshoot the Adobe Connect issues.
* January 24th: Planned maintenance was performed in order to test the routing in the NDGF network.
* January 23rd: SUNET routers were upgraded to a newer JunOS software version.
* January 23rd: An emergency maintenance was performed in order to replace a faulty amplifier card on a SUNET transmission node in Hakkas.
* January 18th: A planned software upgrade maintenance on SUNET's Adobe Connect system was performed.
* January 9th: SUNET's fiber supplier performed cable reconnection work in Stockholm, affecting the West Red and South Red networks.
* January 7th: Planned maintenance was performed to replace defective hardware on a SUNEt router.
{div}
div

Unscheduled:

  • January 25th: A fiber break in Borlänge caused an outage on DU´s redundancy.
  • January 23rd: A transmission card restarted in SUNET's equipment in Umeå, causing an outage on the North Red network.
  • January 22nd: There was an outage on the link to HH.
  • January 17th: A router restarted due to a software bug.
  • January 14th: A faulty transmission card caused outages on the link between Kiruna and Luleå. The faulty card has been replaced.
  • January 5th: A transmission card on SUNET's equipment in Tuggen restarted, causing an outage on the NORTH Red network.
  • January 3rd: A software bug caused a SUNET core router to become unreachable.
  • January 3rd: There was a link outage in Halmstad om the South Green network, no reason for the outage was found.

Scheduled:

  • January 24th: Emergency maintenance was performed in order to troubleshoot the Adobe Connect issues.
  • January 24th: Planned maintenance was performed in order to test the routing in the NDGF network.
  • January 23rd: SUNET routers were upgraded to a newer JunOS software version.
  • January 23rd: An emergency maintenance was performed in order to replace a faulty amplifier card on a SUNET transmission node in Hakkas.
  • January 18th: A planned software upgrade maintenance on SUNET's Adobe Connect system was performed.
  • January 9th: SUNET's fiber supplier performed cable reconnection work in Stockholm, affecting the West Red and South Red networks.
  • January 7th: Planned maintenance was performed to replace defective hardware on a SUNEt router.

    Scope

    Unscheduled

    Scheduled

    Total

    Hardware

    3 pcs 01:32

    2 pcs 00:32

    5 pcs 02:04

    Link

    5 pcs 10:11

    1 pcs 02:19

    6 pcs 12:36

    None

    0 pcs

    0 pcs

    0 pcs

    Routing

    0 pcs

    1 pcs 00:06

    1 pcs 00:06

    Software

    0 pcs

    3 pcs 18:42

    3 pcs 18:42