201305 - Public report
201305 - Public report
Unscheduled:
- May 27th: We experienced a short flap on our west red network. No RFO w=
as found.
- May 24th: A synchronization failure on a transmission card in Karlstad =
caused an outage on the green link to KAU. A restart of the transmission ca=
rd restored the traffic.
- May 22nd: We had a faulty card in our DWDM equipment in Karlstad caused=
outage on the green network. The card was replaced.
Scheduled:
- May 7th: Broken transponder cards were replaced on SUNET transmission e=
quipment in Halmstad.
- May 3rd: Fiber maintenance was performed by carrier on the stretch Bor=
=C3=A5s-Ulricehamn.
- May 2nd: A planned maintenance in the north green network on the stretc=
hes Fredh=C3=A4ll-Uppsala and Fredh=C3=A4ll-Sundsvall was performed.
Scope |
Unscheduled |
Scheduled |
Total |
Hardware |
1 pcs 08:11 |
1 pcs 01:14 |
2 pcs 09:25 |
Link |
2 pcs 00:27 |
1 pcs 00:06 |
3 pcs 00:33 |
None |
0 pcs |
1 pcs 00:01 |
1 pcs 00:01 |
Routing |
0 pcs |
0 pcs |
0 pcs |
Software |
0 pcs |
0 pcs |
0 pcs |
------=_Part_379_1553833274.1711637357193--